Received a document code from UPG?

Enter your 6-digit code to electronically sign your document.

Demand

What is 4CP and how can Texas businesses reduce 4CP charges?

Four‑coincident‑peak (4CP) transmission charges are a cost‑allocation method that ties a commercial or industrial customer’s bill to the four highest summer demand intervals on the ERCOT grid. Understanding how those peaks are selected, how your site’s share of each 15‑minute interval is measured, and which operational levers actually move the needle can shave tens of thousands of dollars off a Texas‑based electricity bill. UPG’s data‑driven approach shows where the savings are real and where the effort outweighs the benefit.

By UPG Market Desk — Texas Commercial Energy Consultants•Published November 18, 2026•6 min read

Thesis

Texas commercial and industrial (C&I) customers pay a portion of ERCOT’s transmission system costs through a four‑coincident‑peak (4CP) charge. The charge is calculated from the customer’s share of the four highest 15‑minute demand intervals that occur each summer (June‑September). By targeting those specific intervals—either through predictive analytics, load‑shifting, or strategic curtailment—a business can reduce its next‑year transmission bill by up to 10‑15%, sometimes more when the baseline demand profile is highly variable. The upside, however, must be weighed against operational complexity, equipment wear, and the risk of missing other cost‑saving opportunities.

How 4CP Works in ERCOT

ERCOT’s transmission cost allocation uses a “coincident peak” methodology that reflects the reality of a constrained grid. The system identifies the four 15‑minute intervals with the highest total load across the entire ERCOT footprint during the summer months. These intervals are called the four coincident peaks (4CP). For each interval, ERCOT calculates a transmission usage factor (TU‑F) for every participating load point based on the proportion of that load’s kW contribution to the total system load at that moment.

The annual 4CP charge for a customer is:

4CP charge = Σ (TU‑F_i × Total Transmission Cost_i)

where i runs over the four peak intervals. Because the total transmission cost for each interval can be several hundred thousand dollars, even a small TU‑F (e.g., 0.02%) can translate into a $5,000‑$15,000 bill line item.

Identifying the Four Summer Peaks

ERCOT publishes the summer 4CP intervals after the season ends, typically in early October. The process is:

  1. Collect 15‑minute load data from all nodes on the grid.
  2. Rank intervals by total system MW.
  3. Select the top four distinct intervals (no two can be within the same hour).
  4. Lock the intervals for the next calendar year’s transmission allocation.

Because the peaks are chosen on a system‑wide basis, they are not tied to any single location. A Texas business in the Dallas‑Fort Worth area may see its highest TU‑F during an interval that is driven by a spike in West Texas wind generation curtailment, a heat‑driven air‑conditioning surge in Houston, or a transmission outage on the Gulf Coast.

Why 4CP Matters for Your Transmission Bill

The 4CP component can represent 10‑30% of a C&I customer’s total transmission expense, depending on the load profile. For a typical $200,000 annual transmission bill, the 4CP portion could be $20,000‑$60,000. Reducing the TU‑F even by 0.01% can move $2,000‑$6,000 in savings.

UPG’s experience with over 8,000 business customers shows that targeted 4CP programs contribute roughly $3.2 M in annual savings across our client base, with individual reductions ranging from 5% to 27% of total transmission spend when combined with broader procurement strategies.

Predictive Services: Knowing the Peaks Before They Hit

Because the 4CP intervals are set after the summer, the only way to act proactively is to forecast the likely peak windows. UPG leverages:

  • ERCOT load forecasts (published 24‑hour and 7‑day ahead).
  • Historical 4CP patterns (e.g., the first peak often falls in late July, the second in early August).
  • Weather analytics (dry heat index, humidity, and wind‑generation forecasts).

Our clients receive a monthly 4CP Outlook that flags the top 10 candidate intervals for the upcoming month, with confidence bands. By aligning demand‑response (DR) events or scheduled process pauses to those windows, a plant can shave its TU‑F before the official interval is locked.

Operational Levers to Reduce 4CP Exposure

1. Load Shifting

Shift non‑essential processes (e.g., batch production, water treatment) to off‑peak hours. Even a 5‑10% reduction in kW during a candidate interval can lower the TU‑F enough to offset the cost of rescheduling.

2. Strategic Curtailment

For facilities with on‑site generation (solar, natural‑gas turbines), curtailing output during a 4CP interval can reduce the net load that ERCOT sees from the node, thereby lowering the TU‑F. This is counter‑intuitive—producing less electricity can reduce a transmission charge—but it works because the charge is based on net load at the node.

3. Demand‑Response Enrollments

Participate in ERCOT’s ancillary services markets (e.g., Regulation Up/Down). When a DR event is called during a 4CP interval, the reduction is automatically credited against the TU‑F.

4. Asset‑Level Controls

Advanced Energy Management Systems (EMS) can automatically shed or stagger loads in 15‑minute blocks. Integration with UPG’s predictive engine ensures the system only acts when the probability of a 4CP interval exceeds a preset threshold (typically 70%).

When Chasing 4CP Isn’t Worth It

Not every business benefits equally. Consider the following signals:

  • Low baseline demand (< 2 MW) – the TU‑F is already minimal; the effort to shift a few hundred kW may not outweigh labor costs.
  • High load factor (> 0.85) – the plant runs near capacity most of the time, leaving little headroom for curtailment.
  • Critical processes that cannot be paused without severe production loss.
  • Contractual constraints such as fixed‑rate power purchase agreements that already lock in transmission cost components.

In these scenarios, UPG recommends focusing on price‑based procurement (e.g., fixed‑rate contracts, block & index structures) that can deliver up to 27% spend reduction across the entire electricity bill, rather than expending resources on marginal 4CP tweaks.

Integrating 4CP Management with a Full‑Spectrum Energy Strategy

A holistic approach couples 4CP reduction with broader procurement and demand‑side initiatives:

  1. Free Energy Health Check – UPG reviews your latest bill and conducts a TDSP delivery‑charge audit to uncover low‑hanging savings.
  2. Supplier Panel Optimization – With a 30‑plus top‑tier supplier panel, we negotiate contracts that lock in transmission components at favorable rates.
  3. Demand‑Charge Management – Align 4CP tactics with demand‑charge reduction (kW‑based) to capture double‑digit savings.
  4. Continuous Monitoring – Post‑summer, we compare actual TU‑F against forecasts to refine the model for the next year.

Bottom line

4CP charges are a predictable, but potentially sizable, portion of a Texas C&I transmission bill. By understanding how ERCOT selects the four summer peaks, leveraging predictive analytics, and applying targeted load‑shifting or curtailment, a business can reduce its 4CP exposure by several thousand dollars annually. However, the effort must be justified against operational constraints and overall cost‑saving priorities. When the ROI on 4CP tactics falls short, UPG’s broader procurement and demand‑charge programs typically deliver larger, more reliable savings.

What is 4CP and how can Texas businesses reduce 4CP charges? — quick questions

Ready to take control of your energy costs?

Send one recent bill and a UPG advisor will run your free Energy Health Check — TDSP fees, contract terms, renewal windows — with a written summary back to you.